Magnets

Metal Detector Verification Guide.

metal detector

The guide to metal detector verification


Metal Detector Verification 101

Metal detectors used in food processing are essential to keeping hazardous metal particles from mixing into our food. Ensuring a metal detector is operating properly and is properly verified will keep your metal detector operating properly for its lifespan. This article will go over the process of verifying an industrial metal detector. 

 

Calibration vs Verification

When it comes to verifying a metal detector, it is essential to understand the difference between calibration and verification. Metal detector calibration is a different process compared to calibrating a scale. When it comes to ensuring that the metal detector is able to perform its task, then it goes through a verifictaion process. Verification is the act or process of proving that the metal detector meets its sensitivity requirements. This is accomplished by challenging the detector in a repeatable manner with a certified metal sphere at a pre-described time. Most often, this procedure is executed at the same time on a daily basis. Unfortunately there is no standard to which a metal detector can be set. Granted we use metal detectors to find a specified size of metal during processing.  Setting the metal detector to pick up a specific size of metal will help locate a range surrounding a specific size. A good example of this is to change the settings to s epcific size and the magnet should be able to detect 1.5mm ferrous.  Even though a metal detector can’t be calibrated, it detector can be verified and validated. The metal detector can be tested to ensure it qualifies as meeting the standards set forth in a HACCP or other plan.

One would think that verifying a metal detector would be similar to calibrating a scale, this is not the case. With a scale, you take a standard weight, lets say 10lbs and adjust the scale so that it reads 10lbs.  You might send out a scale to a 3rd party vendor who would ensure that the device is calibrated, usually to an specifically accepted standard, and measured appropriately and consistently.

Metal Detection Standards

Unlike an industrial scale, a metal detector does not have an international standard to follow to be considered calibrated (industrial scales have NSIT). There are a lof factors that can affect detectors capabilities. This section will go over the factors that affect metal detectors.

  • Orientation effect – Happens when the diameter of a wire contaminant is less than the spherical sensitivity in the test piece.  Sensitivity is measured by the ball size because some contaminants, which are often wire, are more difficult to detect based on the direction of travel through the aperture.

  • Aperture size and position – A contaminant close to the wall of the metal detector is easier to detect. The larger the aperture, the less sensitivity. For a consistent reading, products should pass directly through the center of the aperture.

  • Packaging material – The material used to pack a product also affects sensitivity. Any metal in the packaging will affect the metal detector, reducing sensitivity and possibly creating a false metal signal.

  • Environmental conditions – Vibrations and temperature fluctuations can affect the metal detector’s sensitivity.

  • Product characteristics – Some products have certain characteristics that behave in the same way as metal when passing through the detector. For example, products with high moisture or salt content, such as meat and poultry, can often create a ‘false’ signal, making it difficult to distinguish the difference between metal and product.

  • Process speed – This is not necessarily a limiting factor for conveyorized metal detectors where product passes through at a consistent speed, but performance is hindered when inspecting product passing through vertical metal detection systems pipelines because of the variations in the speed and flow of the product.

  • Detector frequency – Metal detectors operate at different electromagnetic frequencies depending on the type of product being inspected.

understanding Verification

While all these are important considerations, these are only some of the factors involved in veritying and validating a metal detector. All things being considered, the term calibration applies, ultimately, to the relationship between the metal detector and the product. Once the proper size aperture is available and each of these factors have been settled, a metal detector is “calibrated” with clean/non-contaminated product such that the product does not cause any effect on the metal detector. In simple terms, run a clean product through your detector and it shouldn’t reject the product.  The “Product Effect” is being eliminated from the testing process.

Product effect is the magnetic and conductive properties of a product. As the product passes through the aperture, it will affect the coils used in the detection process.  Metal detectors must factor this and eliminate it or ignore it. During setup, the detector needs to “learn” what is the product effect.  The detector will discover this (along with the other factors above) and can then be set to a baseline.  This is a setting in which the product (a clean product) and it’s container (paper, cardboard or other non-magnetic housing) move through the detector without setting off a detection alarm and the associated reject device.

When it comes to an audit, many people will ask an auditor to come in and “calibrate” their detectors. An auditor can assist with that, as explained, but that’s not what’s done during an audit.  The auditors job is to verify that the metal detector can achieve the specifications (usually of a HACCP plan) that the quality control department needs it to achieve.  An auditor should be able to discuss calibration and verification.

Testing Workflow

The metal detector test follows a specific flow, which helps ensure that there aren’t any skips in procedure. Below is a list of what to expect when getting your metal detector audited.

  1. The auditor will confirm that the test samples are clearly marked with size, composition, and certificate number or provide. Whenever possible, Detector Audits will supply certified test samples for testing.

  2. Unit will be monitored/observed with a product to watch for signal changes and potential interference sources.

  3. Settings will be recorded as found at time of arrival, prior to making any changes to the unit.

  4. Test samples should travel through the approximate centerline of the aperture as this is the least sensitive area of the aperture.

    • Samples should be placed within the product when possible.

    • Testing of conveyor units should be tested on the product, preferably in the lead/center/trail position.

    • Gravity units should be tested from point of product freefall.

    • Testing of pipeline units should be tested through the center of the pipe.

  5. Test samples must activate the reject device to ensure the reject device is properly removing contaminated products from production. Verifying the reject device may include:

    • Testing with contaminant at leading and trailing edge

    • Running successive packs

    • Attempting alternate packs

  6. Testing will be performed 3 times per test sample. A successful test consists of 3 (per test sample) consecutive detects.

  7. Changes to unit settings will be made, as necessary, to achieve successful testing. All changes will be recorded. These alterations should be made by plant personnel whenever possible.

Conclusion

So if the company (customer) has already established that they need to achieve 1.5mm Ferrous, 2.0mm Non-Ferrous and 3.0mm Stainless Steel, then the auditor, using a procedure outlined above, will verify that standard.  If the product changes, the standards achievable could change, so the verification only applies to the products tested on that metal detection system. A change in the product will require that the detector be re-calibrated for that product and then the auditor can verify it meets the standards intended.  Understanding the terminology means clarifying what you do on your production line and how it’s done. And in the end analysis, that makes for a safer product in the marketplace, so know the difference between calibration and verification.

At American Scale we strive to bring you informed and useful content on all things scale systems related, including products from the top scale manufacturers. Be sure to check out our truck scale articles about truck scale foundation or how much do truck scales cost. We even have a guide to warranties. To learn more about bench scales, it would be good to check out our other articles such as “Bench Scale Basics'' andHow Much Does A Bench Scale Cost?”. These articles will help with the basics of bench scale ownership. Also, take a look at our“Common Problems With Bench Scales'', to help prolong the lifespan on your scale.

How To Test My Magnet?

Magnet-Audit-300x300.jpg

Testing Your Magnet

Because magnetic fields are transparent to the human eye, measuring their strength requires specialized tools that measure the working air gap of the magnetic circuit. Currently, there are two accepted ways of testing your magnetic separation equipment and this subject itself is not without controversy. The first is with the use of an instrument called a Gauss Meter or Magnetometer and a probe, and the second is with a Pull Test Kit using a scale and a selection of different sizes of ferrous test pieces; a ¼” ball, a ½” ball, a 1” ball and a 1” x 3” plate. Make sure you understand the different type of magnets prior to testing, checkout this blog post to learn more.

Gauss Meter

A Gauss Meter is an electronic device that measures the flux density at any given point on your magnet. As the probe is pressed against the surface of the magnet it senses the flux density and translates it into an electrical voltage read by the gauss meter. Gauss readings are displayed on the meter. When the maximum number is found while moving across the face of the magnet (usually at a pole piece), it is recorded.

PROS

It is a scientific piece of equipment that can be calibrated. In clinical environments where the working air gap can be plotted and the probe placed repeatedly in the exact same spot within the gap, Gauss is incredibly accurate.

CONS

In real-world environments Gauss testing has serious limitations. Gauss profiles change significantly depending upon the location and angle at which the probe is placed within the working air gap in relation to the line of flux travel. Because magnet circuits vary from one magnet to the next, and because of “human error,” accurate readings are difficult to attain making the manually taken gauss value an imprecise determination of the magnets strength. Simply placing a different amount of pressure on the probe to the surface of the magnet will create drastically varying results. Because of the length of time that lapses between testing, it is not uncommon for different individuals to execute them, which further limits accuracy. Lastly, any mechanical damage to the probe or cable will degrade the precision of the instrument. They are essentially “consumables” that require regular replacement. These factors add time, cost, and technical training to the equation.

MPI’s Magnetic Pull Test Kit

A Pull Test Kit utilizes a compact digital scale or a spring scale, and a series of ferrous test fixtures (a ¼”, ½”, and 1” ferrous ball and 1” x 3” ferrous plate). The magnetic pull strength is measured by using the calibrated scale and a ferrous test piece to determine the breakaway force, typically measured in pounds or ounces. The test fixture has one end attached to the scale and the other end securely attached to the working area of the magnet at a predetermined position (on the surface with a specified air gap). It is then slowly pulled away at a perpendicular direction to the magnet until it is released. The pull strength is registered on the scale.

PROS

The digital scale offered in MPI’s Pull Test Kit is also a scientific device that can be calibrated and NIST (National Institute of Standards and Technology) certified. In practical applications, the pull test approach is advantageous because the testing equipment is less expensive to acquire, more efficient to operate, and achieves more consistent repeatable values than the gauss approach regardless of the individual operator. The ferrous test fixture is drawn to the magnets peak energy point with every repetition of the test, as opposed to the gauss approach which requires the operator to find the peak energy point within the working air gap using the probe. The pull test is also performed much more efficiently than the Gauss method, minimizing production downtime.

CONS

Just as Gauss meters have evolved over the years, so have mechanical pull test kits. Akin to a fish scale, some company’s pull test kits are still offered with simple spring-loaded gauges that measure the force required to pull a small metal sphere or ball. MPI’s magnetic pull test kit is the most accurate and easiest method to test the strength of your magnets. This easy-to-use, compact gauge fits into tight areas and is battery- operated (four AA batteries included.). Boasting a capacity of 44 lbs. (20 kg), MPI’s magnetic pull test kit can measure pull in pounds, ounces, kilograms, newtons, or kilonewtons. It can maintain the last reading after release. Packaged in a hard-sided foam-padded carrying case, this compact unit includes all needed accessories and can be used to test a complete range of magnet types and configurations. The documentation generated from this test can be used for compliance in a Hazard Analysis and Critical Control Point (HACCP) plan or for documentation requirements under the Food Safety Modernization Act (FSMA).

To learn more about the magnets that American Scale offers click here.

How Often Should I Clean My Magnet?

cleaning-your-magnet3.jpg

How often Should I Clean My MaGnetS?

How often should you be cleaning your magnet is another question that is dependent upon your individual process. Obviously, the more metal you receive or produce in your process, the more frequently you should be cleaning your magnets. A general rule is the more frequently, the better. As a magnet gathers ferrous metal, the magnetic field is dispersed over a larger surface area. This happens because ferrous metal is paramagnetic, meaning it takes on the properties of the magnetic field. When this happens, the magnetic field strength is reduced. It is better to begin cleaning your magnets more frequently after the magnet is placed and reducing the frequency as possible without jeopardizing the effectiveness of the piece of equipment. Each manufacturing facility will be different as well as locations within the same facility may very well need to be cleaned at different intervals. “More is better.” To learn more about the lifespan of a magnet checkout this blog post.

Establishing A cleaning schedule:

1. After installation, inspect your magnet after the first hour of production

2. If an insignificant amount of metal is observed, return in 2 hours to inspect magnet

3. If magnet continues to have insignificant amount of tramp metal, it is recommended that maximum time between cleaning is 8 hours

4. If significant amount of metal is found on magnet, increase the cleaning interval as required to ensure the magnet does not reach maximum tramp metal capacity

Key to magnet performance is also testing, checkout this blog post to learn more about testing your magnets to ensure proper function.

What's The Lifespan Of A Magnet?

 
 

How Long Will My Magnet Last?

Your permanent magnet should lose no more than 1% of its magnetic strength over a period of 100 years provided it is specified and cared for properly. There are a few things that may cause your magnet to lose its strength:

HEAT:

Heat above the maximum level rated for the magnet material in your separator will decrease the strength of the magnet. Standard rare earth material from MPI has a maximum temperature of 176°F and standard ceramic material has a maximum temperature of 400°F. Higher temperature materials are available and may have been used in your system. Consult the factory if you have questions on what the maximum temperature is for your system.

IMPACT

Sharp impacts to the magnet from physical abuse or handling can result in the decreased magnet strength. The magnet material inside your separator is brittle and these impacts can lead to fractures in the material, weakening its strength.

WELDING

Welding on or around the magnet can lead to decreased magnet performance. This can be a result of the heat or current generated from the welding process.

LIQUID INGRESS

If your magnet housing is compromised, moisture can enter the housing of the magnets. This can lead to oxidation of the magnet material which will eventually lead to a weakened magnetic system. If the housing is compromised, the magnet should also be replaced for sanitary concerns.

Closing Words

At American Scale we strive to bring you informed and useful content on all things scale related. Be sure to check out our legal for trade truck scale system articles about truck scale foundation or how much do truck scales cost. We even have a guide to warranties. We also have articles on scale accessories, common problems to prolong your scales lifespan, weighing applications as well as what scale indicator works best with your junction box. To learn more about bench scales, it would be good to check out our other articles such as “Bench Scale Basics'' andHow Much Does A Bench Scale Cost?”. These articles will help with the basics of bench scale ownership.

Magnets: What Are The Different Types?

Magnets magnetically capture and control ferrous contaminants in material process systems. The proper magnetic applications and magnet placements will help you achieve success for removing tramp metal from your product flow.

Magnets magnetically capture and control ferrous contaminants in material process systems. The proper magnetic applications and magnet placements will help you achieve success for removing tramp metal from your product flow.

Magnetic Application – Primary Magnets

Primary magnets are designed to be used in high volume process flows placed inline so as not to introduce any foreign contaminants from external sources into your production facility. They will remove large amounts of ferrous tramp between cleaning cycles giving you peace of mind. These magnets are typically located in plant receiving areas and handle large amounts of materials that tend to damage equipment or bridge in many magnet applications. The magnet circuit design is such that the magnetic field reaches out is maximized while maintaining adequate holding values to gather large amounts of tramp before reaching the saturation point. Primary magnets help to identify risks associated with bringing in ingredients from outside sources allowing you to monitor your vendor product quality.

Primary Magnet Function:

  • Process high volume product flows

  • Remove incoming tramp ferrous

  • Retain large volumes of tramp ferrous between magnet cleaning cycles

  • Vendor monitoring

Where it is used:

Plant receiving areas

MPI Primary Magnets:

Chute Magnets, Free-Flow Magnets

Magnetic Application - Secondary Magnets

Secondary magnets are used in processing areas in front of sensitive pieces of equipment for protection, as well as throughout your process for redundancy which helps to detect process equipment malfunctions. The material flow is typically metered at this point, which enables us to specify your exact application requirements. The magnetic circuits are designed with specific functions, whether that be to maximize the magnetic fields reach out, holding force, or a combination of both.

Secondary Magnet Function:

  • Protect specific plant equipment

  • Detect process equipment malfunctions

Where it is used:

hammer mills, airlocks, screw conveyors, sifters, roller mills, bucket elevators, screeners, pumps

MPI Secondary Magnets:

Plate Magnets

Magnetic Applications Finishing Magnets

The function of a finishing magnet is to maintain your end product quality to your customer. Finishing magnets capture small metal fines from your process ensuring product shipped from your plant, whether going to another manufacturer for further processing or to a shelf for consumer use, contains no ferrous tramp contamination. This protects your brand reputation and financial liability for recalls, as well as consumer protection.

Finishing Magnets Function:

  • Maintain end-product quality

  • Ensure that the product to be shipped from the plant does not contain any tramp ferrous contaminants

  • Consumer protection

  • Brand protection

Where it is used:

packaging systems, bulk load-out areas

MPI Finishing Magnets:

Tube MagnetsGrate MagnetsDrawer MagnetsPneumatic Line Magnets

So what is the best type magnet for my application?

That depends on your reason for looking into magnetic separation equipment, to begin with. Are you looking to protect equipment or the integrity of your product? Your desired results will determine which type of magnet to put into place and where. Keep in mind that no magnet is 100% effective in removing all tramp metal. The amount of tramp it is exposed to couple with the frequency of cleaning has a dramatic effect on your success. If you are finding a lot of metal on your magnet, you can be fairly certain metal has gotten by. Because of this, redundancy in your process is critical with magnetic separation equipment. You should feel comfortable in the amount of metal you are collecting on the last magnet in your process.

Closing Words

At American Scale we strive to bring you informed and useful content on all things scale related. Be sure to check out our legal for trade truck scale system articles about truck scale foundation or how much do truck scales cost. We even have a guide to warranties. We also have articles on scale accessories, common problems to prolong your scales lifespan, weighing applications as well as what scale indicator works best with your junction box. To learn more about bench scales, it would be good to check out our other articles such as “Bench Scale Basics'' andHow Much Does A Bench Scale Cost?”. These articles will help with the basics of bench scale ownership.